Parker’s direct operated directional control valve series D1VW with inductive position control in NG06 (CETOP 03 / NFPA D03) features low energy losses due to optimized flow passages. It offers high functional limits up to 80 l/min and a maximum pressure of 350 bar.
This on/off valve is typically used in safety relevant applications. It complies with the machinery directive 2006/42/EG for use as clamping valve according to EN 201:2010. The start or the end position can be monitored. The position control is available for single and double solenoid valves.
Markets:
• Industrial
• Molding
Features/Benefits:
• High functional limits – low forces resulting in safe operation also at high flow rates
• Low pressure drop – resulting in low energy losses in operation
• Wide product offering – many different options – all valves from one single source
• Short delivery time – no warehousing necessary
Applications:
• All types of safety relevant applications
• Injection molding (safety component according to machinery directive 2006/42/EG)
Attention:
The adjustment of the position control is factory set and sealed. Replacement and repairs can only be undertaken by Parker.
The fail-safe position of the directional valve during power failure is the spring offset or center position.